TonoVue-P Non Contact Tonometer with Pachymeter

tonovuep  ürünler

*

Automatic Non Contact Tonometer with Pachymetry
TonoVue-P

The TonoVue-P combines IOP and central corneal thickness (CCT) measurements in a single unit.

3D Auto Tracking

Automatic tracking and automatic alignment of the pupil with a single touch.

CCT Measurement

The TonoVue-P is equipped with the function of measuring central corneal thickness (CCT).

Auto Cutter

Built-in thermal printer and automatic cutter.

All Done by Single Tap
With fully automatic 3D tracking technique, multiple IOP measurements can be done by single tap on the screen. Simply click ‘start’, the examination will begin and the result will be printed out directly.

Auto CCT Measurement
Taking the technology of Scheimpflug camera and 3D auto tracking, TonoVue-P provides safe, easy and accurate measurement for central corneal thickness (CCT).
Large Screen and Touch Panel

The large 10'1" screen and touch panel is easy to control, making IOP measurement simple and fast. It also makes input, search, and display of the patients' database easy.

Multiple Selectable Modes
Users are able to select either automatic or manual mode, set 1-3 times of measurements, and adjust IOP range based on their preference and patients ‘needs.

tonop2

Patient Friendly - Smooth and Fast

The Automatic Air Puff Control System controls the amount of air required for each individual eye.

. It provides a softer and quieter blow of air that makes the patient feel less uncomfortable.

. With intelligent 3D monitoring, measurements can be made quickly and precisely.

It not only simplifies the inspection process, but also shortens the inspection time.

It reduces discomfort or tension for doctors and nurses, but also for patients.

 

Calculation of Compensated IOP

Studies say that measuring the thickness of the central cornea (CCT) can affect the accuracy of IOP

. For example, thinner corneas contribute to underestimation of IOP. TonoVue-P provides compensated IOP values: automatic measurement of CCT values. The compensated IOP formula can also be customized by the user.

Specification
Model Name: TonoVue-P
Type Automatic Non-Contact Tonometer with Pachymetry
Central Corneal Thickness Measurement range 0.40 – 0.80 mm
Central Corneal Thickness Light source Blue LED
Intraocular Pressure Measurement range 1– 60 mmHg
Measurement range setting Auto/ 30 mmHg/ 60 mmHg
Measurement principle Air puff method
Display units mmHg/hpa
Working distance 11 mm
Alignment Fully automatic 3D tracking
Chinrest Motorized
Display 10”1 LCD touch screen
Printer Thermal line printer
Interface USB / RS232
Power supply AC100V to 240V, 50/60Hz, auto selected
Operating Environment Temperature: 10℃ to 35℃; Humidity: 30% to 90%
Dimensions (WxDxH) 282 mm x 500 mm x 500 mm
Weight 17 Kg

Leave a Comment