MOCEAN 4000 SLO-OCT

MOCEAN 3000 urunler

Overview

High scanning speed at 80,000 A-scans/s

Up to 100 images averaging enhances the quality of OCT imaging

3mm scan depth shows better details of the vitreous, retina and choroid

Real-time 45° SLO retinal imaging

SLO-based retinal tracking

16mm angle-to-angle scan

Comprehensive analysis of retina, glaucoma and cornea

Upgrade to VASCAN OCTA analysis (optional)

Ability to take up to 100 B scan images from a single line with 5micron optical resolution to improve the quality of the OCT image.Superior OCT image quality with up to 100 times averaging

Mocean 4000 captures 100 images in less than one second, and merge them together to create a high definition image with minimized speckle noise

5 μm axial optical resolution (3 μm digital)

High definition OCT imaging reveals hidden pathological changes

Deep Choroidal Imaging (DCI) mode

Using Deep Choroidal Imaging for detection of choroidal neovascularization.

High quality real-time SLO + Eye tracking

The key advantage of Mocean® 4000 system is the simultaneous acquisition of cross-sectional OCT imaging and 47 degrees fundus imaging based on Scanning Laser Ophthalmoscope (SLO). It gives you an overview of the retina so you can easily locate the lesion area before acquisition. Moreover, the system captures up to 50 SLO fundus images within one second in order to generate an HD fundus imaging with
To minimize the artifacts caused by eye drift and micro saccades, Mocean® 4000 uses SLO-based eye tracker. It performs 100 times tracking per second with 10 microns tracking accuracy and more than 95% success rate, which gives you more confidence in practice.enhanced signal-to-noise ratio.

Comprehensive GLAUCOMA analysis (ONH/GCC)

For comprehensive glaucoma analysis, Mocean 4000 offers two scan patterns, glaucoma cube scan in macular area for GCC analysis and glaucoma cube scan in disc area for ONH analysis. Evenly distributed sampling point with 200 x 200 A-scans provides reliable information for early glaucoma detection and management.

16mm angle-to-angle analysis

16mm angle-to-angle anterior scan with data analysis

6 mm Pachymeter and Epithelial Thickness Map

Comprehensive software analysis and free upgrade

The Mocean® 4000 system provides 8 scan patterns to help you improve diagnostic efficiency:

Retina (HD line, Six-Radial lines, Multi, 3D Cube)

Glaucoma (Glaucoma Disc for ONH analysis, Glaucoma Macular for GCC analysis)

Cornea (HD line, Six-Radial lines, Angle-to-Angle)

Optional VASCAN™ OCTA Module

*VASCAN™ OCT Angiography module is an optional software module of Mocean 4000.

Optical Coherence Tomography Angiography (OCTA) is a new non-invasive imaging technique that allows the detailed study of flow within the vascular structure of the eye without the need of dye injections.

 · Ultraclear angiographic imaging powered by COMAG algorithm using phase and amplitude signals

· Widefield OCTA imaging up to 12 mm x 8 mm